Displacer Level Switches
DISPLACER LEVEL SWITCHES are the most versatile for level control and have advantages over float type switches in the control of agitated liquids paints-varnishes & heavy oil and foaming liquids. The Displacer weight is heavier than the liquid which is suspended by a spring. When the liquid rises the displacer looses the weight, this causes the spring to retract slightly to a new equilibrium position. This retract of the spring interchanges the position of the Magnet provided at the top and actuates the switch. Upto three independent switch junctions are available in the single unit, with broad choice of operating sequences. These are flange mounted and are available with a choice of material of construction.
It is based on buoyancy principle and is available in different material of construction for a variety of switching functions. The instrument can be used for level switching function in large tanks upto 15m, in turbulent liquids and even without steel pipes. The switch position can be adjusted at site depending upon the requirement. It works reliably upto 200ºC temperature & 40 Kg/cm² pressure. The Material of construction may be MS, SS304/SS316 or PP and the enclosure protection confirms to IP56/IP65/Ex-proof IIA & IIB or IIC. It is economical for large vessels and can be easily transported.
Dislacer Level Switch Features
- Based on Buoyancy Principle, displacer suspended by a spring
- Versatile for level control and have advantages over float type switches
- Best for agitated liquids like - paint & varnishes, heavy oil and foaming liquids
- SS 304/SS 316/PP/PTEF Displacer
- Explosion Proof/Weatherproof Connection Box
- Standard upto 15 meter length
- Single/Multiple Displacers, max upto 3 displacers
- Micro Switch Operated rated at 5 or 15 Amp 220 VAC
- Displacer Adjustable at any point
A | SITE CONDITIONS | ||
01 | Ambient Temperature (Max) | 55°C | |
02 | Relative Humidity | 100% RH (Max) | |
B | PROCESS CONDITIONS | ||
01 | Fluid | Gas (Upper) Solvent(Lower) | |
02 | Normal/Max. Pressure | 1 Bar / 10 Bar | |
03 | Temperatures | Ambient | |
04 | Density of Fluid | 700 Kg/m³ on and above | |
05 | Rope Length | As per requirement, upto 15 meter | |
C | TECHNICAL PARTICULARS | ||
01 | Tag Number | - | |
02 | Type | Displacer | |
03 | Enclosure | Cast Al. Alloy, Weather Proof/Ex-Proof | |
04 | Number of Displacers | One / Two / Three | |
05 | Shape of Displacer | Cylindrical | |
06 | Mounting | Top of the tank | |
07 | Gaskets | - | |
08 | Degree of Protection of S/W Housing | IP66 As Per IS:13947 | |
09 | Adjustability of Set Point | Throughout the Length of Wire Rope | |
10 | Differential | 30 + 5 mm (Fixed) | |
11 | Process Connection | 2” NB/3” NB CS Flange | |
12 | Repeatability | (+/-) 3 mm | |
13 | Max. Working Temperature | 2000°C | |
14 | Max. Working Pressure | 10 Bar | |
15 | Electrical Cable Entry | M20x1.5 | |
16 | Activating Switch Type | Micro-Snap Action, SPDT | |
17 | Switch Adjustability | Internal with fixed differential | |
18 | Number of Contacts | 1 C/O, SPDT per Displacer | |
19 | Contact Rating | 5 Amps, 220 VAC | |
D | MATERIAL OF CONSTRUCTION | Italy | |
01 | Displacer | SS 316 / SS 304 | |
02 | Wire Rope | SS 316 (Multistrand) | |
03 | Spring Housing | S. Steel | |
04 | Spring | Spring> | |
05 | Sleeve Pipe | AISI 316 | |
06 | Magnetic Sleeve | AISI 410 | |
07 | Mounting Flange | MS, Powder coated/Painted | |
08 | Switch Housing & Cover | Cast Alluminium Alloy | |
E | ACCESSORIES INCLUDED | ||
01 | Tag Plate | Yes (MOC – Alluminium) | |
02 | Guide Pipe | As per requirement | |
Qty | |||
Unit Rate |
If you require Displacer Level Switches, get in touch with us today. We are always ready to fulfill your requirements.
Get in Touch with us
- 36-1-A Abhishek Complex, B Wing, 38A, Opp. Bank Of Baroda, GIDC Makarpura, Vadodara- 390010, Gujarat, India
- (+91) 9638370219
- veksler2007@gmail.com
- pradeep@vekslerindia.com